Back to All Industries
Instant audit-ready eDHR, UDI & CAPA documentationOdoo

Odoo ERP for Medical Device ERP & QMS (ISO 13485)

Audit-ready ERP and Quality Management System (QMS) for medical device manufacturers, importers, and hospital suppliers. Enforce ISO 13485 controls, UDI serial traceability, Electronic Device History Records (eDHR), CAPA, and hospital biomedical AMC servicing.

End-to-End Automated Workflow
01Design & ISO 14971
02eDHR & UDI Serial
03QC & CAPA Gate
04Hospital / NUPCO Supply
05Biomedical AMC & ZATCA

Odoo Interface Gallery

Stream-branded, watermark-free Odoo workspace screens — click any view to zoom

1 / 3
Medical Device QMS · ISO 13485, UDI & CAPA — 1. Executive Cockpit
Original Application Screenshots (10 Live Screens)

Authentic Original Odoo Workspace Screenshots

Real in-app screenshots captured from the merged Odoo modules included in this industry suite — click any screen for full-resolution zoom.

Core Sector Capabilities

  • Full ISO 13485 Quality Management System with document control, e-signatures & training records
  • Electronic Device History Record (eDHR) & Unique Device Identification (UDI) serial tracking
  • ISO 14971 Risk Management, Non-Conformance Reports (NCR), CAPA & vigilance complaint handling
  • SFDA MDMA registration expiry tracking & NUPCO/hospital tender supply scheduling
  • Biomedical field-service calibration & preventive maintenance contracts for installed hospital devices

KSA Compliance & Integrations

SFDA MDMA/UDI regulatory tracking, ISO 13485/14971 audit packs, NUPCO tender compliance & ZATCA 0% qualifying medical-device VAT.

Core Odoo Apps
Odoo ManufacturingOdoo QualityOdoo PLMOdoo InventoryOdoo Field Service
Stream Vertical Modules
Stream Medical Device ERP & QMS
ISO 13485 QMS, ISO 14971 risk matrix, UDI barcoding, eDHR, CAPA & validation pack
Complete Unabridged Functional Specifications (1 Suite · 11 Sections)

Every Merged Module Capability & Technical Detail

Full unabridged documentation of all merged modules, workflows, cockpits, and technical engines deployed by Stream on Odoo.

Odoo Suite · 11 sections

Medical Device ERP & Quality Management Suite (QMS)

11 QMS Executive Dashboards & Regulatory Readiness

Eleven quality and regulatory dashboards unite operational ERP execution with ISO 13485 and EU MDR oversight, opening each board with the most critical pending issue.

Quality leaders review real-time indicators, inspect audit readiness verdicts, and export any visual view as structured tabular data.

  • Quality Pulse executive dashboard highlighting the top open compliance issue alongside live counts across every QMS register.
  • Design & Traceability and Risk dashboards tracking stage-gate status, user-need-to-validation gaps, residual risk movements, and open FMEA reviews.
  • Production & Release and Suppliers dashboards spotlighting batch records ready for QA review, blocked releases, open SCARs, and expiring vendor certificates.
  • Complaints, Vigilance, CAPA & Post-Market boards placing the shortest statutory reporting clock first while separating overdue CAPAs from pending effectiveness checks.
  • Equipment, Validation & Training dashboards tracking upcoming calibrations, revalidations, and personnel lacking sign-off on current SOP revisions.
  • Regulatory Readiness matrix evaluating ISO 13485 clauses and MDR articles with live supporting evidence and Ready, Partial, or Gap verdicts.
Device Master File, Technical Documentation & UDI Registry

Layer regulated device metadata—Basic UDI-DI, risk classification, Annex II/III indices, and Declarations of Conformity—directly over native Odoo product records.

Keep regulatory evidence current across device families, packaging levels, notified body certificates, and applicable standards editions.

  • Device family master records holding Basic UDI-DI, classification rules with written justifications, intended purpose, and market applicability flags.
  • Device and variant registry assigning packaging-level UDI-DI identifiers, nomenclature, shelf life, and storage conditions to underlying inventory products.
  • EU MDR Annex II and Annex III technical documentation index measuring section-by-section completeness prior to notified body reviews.
  • Notified body and ISO 13485 certificate register tracking scope and expiration dates alongside versioned, signed Declarations of Conformity and editable standards reference logs.
Controlled Documents, Training & Role Competence

Govern SOPs, work instructions, and quality records through formal review, approval, e-signature, and periodic review cycles.

Automatic training triggers and role-based competence matrices ensure only qualified staff execute regulated production steps.

  • Controlled document lifecycle tracking effective versions, document owners, periodic review due dates, and full revision history.
  • Multi-step electronic review and approval workflows capturing e-signatures at every stage.
  • Automated read-and-understood training tasks dispatched to relevant personnel whenever a controlled document reaches a new effective revision.
  • Role-based competence matrix verifying operator qualifications before scheduling or allowing shop-floor step execution.
Design & Development Controls (ISO 13485 7.3) & Traceability

Manage structured medical device engineering projects from initial user needs through design transfer using enforced gate reviews and live traceability matrices.

Change requests assess risk, verification, labeling, and regulatory impacts before modifications proceed.

  • Phased design projects tracking plans, stage gates, assigned responsibilities, and linked deliverables.
  • Live end-to-end traceability matrix mapping user needs to design inputs, design outputs, verification, and validation with automatic gap highlighting.
  • Formal design review records documenting attendees, independent reviewer enforcement, review findings, and follow-up actions.
  • Significant change control impact assessments and design transfer checklists confirming production specification readiness.
ISO 14971 Risk Management & Integrated FMEA

Connect hazard analysis directly to design and process FMEA through shared risk controls, ensuring process findings feed automatically back into the risk management file.

Configure device-family severity scales, probability ratings, and risk acceptability matrices aligned with internal procedures.

  • Device-family risk management plans defining custom severity scales, probability levels, and risk acceptability matrices.
  • Before-and-after risk matrices visualising hazardous situations prior to and following risk control implementation.
  • Comprehensive risk register recording hazards, sequences of events, potential harms, initial risk, controls, and residual risk.
  • Unified dFMEA and pFMEA linked to the same risk controls, plus automated risk reviews triggered by complaints, nonconformances, and PMS trends.
Supplier Control & Incoming Inspection (ISO 13485 7.4)

Prevent unapproved procurement of critical components while maintaining complete supplier audit, quality agreement, and incoming inspection records.

Statistical acceptance sampling plans govern quarantine and lot release decisions.

  • Approved Supplier List displaying qualification status and criticality, warning or blocking purchases from unapproved critical vendors.
  • Unified supplier profiles consolidating evaluations, audits, quality agreements, expiring certificates, and open SCARs.
  • Periodic supplier scoring against weighted criteria with scheduled re-evaluation tracking.
  • Incoming material inspection executing custom sampling plans—backed by a binomial sampling calculator—to release or quarantine received lots and issue SCARs.
Electronic Device History Record (eDHR) & Shop-Floor Controls

Lock manufacturing orders strictly to approved production specification versions and consolidate every shop-floor activity directly onto the finished lot's Electronic Batch Record.

Built-in manufacturing, inventory, sales, and accounting integration preserves accurate stock valuation and end-to-end forward customer traceability.

  • Versioned, locked production specifications ensuring manufacturing operations execute solely on QA-approved revisions.
  • Complete lot-level eDHR capturing consumed material lots, process parameters against tolerance limits, operators, equipment, inspections, and deviations.
  • Interactive shop-floor station scanning batch barcodes, enforcing active operator training and valid equipment calibration, and validating entered parameters.
  • Mandatory re-authenticated e-signatures stating signer identity, timestamp, reason, and signature meaning.
  • Automated QA release blocks while any deviation, nonconformance, or required inspection remains open, paired with forward lot/serial consignee traceability.
Process Validation, Calibration, Cleanrooms & Sterilisation

Monitor validated special processes, equipment calibration status, cleanroom environments, and sterilisation cycles with direct interlocks to production.

Any out-of-tolerance equipment reading immediately identifies every manufactured lot potentially affected.

  • Special process validation registry tracking IQ, OQ, and PQ protocols, reports, and revalidation dates with shop-floor warnings if validation lapses.
  • Equipment register tracking calibration and preventive maintenance histories alongside impact tracing across lots touched by out-of-tolerance instruments.
  • Cleanroom environmental monitoring logging particle counts, microbiology, differential pressure, temperature, and humidity against control limits.
  • Automated excursion assessment escalating out-of-limit cleanroom readings to nonconformances, plus sterilisation batch load and release records.
UDI Labeling, Reconciliation & Regulatory Data Exports

Generate GS1 DataMatrix labels with human-readable interpretation and enforce full label reconciliation before QA batch release.

Prepare validated XML and HL7 SPL export files ready for EUDAMED and GUDID portal uploads.

  • Lot-level UDI records combining UDI-DI and UDI-PI with compliant GS1 application identifiers, plus identifier recording for HIBCC and ICCBBA.
  • Versioned device label templates enforcing market-language completeness before revision approval.
  • Strict lot label reconciliation verifying printed, used, spoiled, and returned quantities balance prior to QA release.
  • Preflight gap checks and export generation for EUDAMED bulk XML and GUDID HL7 SPL records (with user-licensed GMDN codes) ready for manual regulatory upload.
Nonconformance, MRB, CAPA, Complaints & Post-Market Surveillance

Manage quality events across the entire product lifecycle—from incoming and production nonconformances to customer complaints, vigilance reporting, field recalls, and PSUR reporting.

Structured investigation tools ensure root causes are verified and effectiveness is proven before CAPA closure.

  • Nonconformance intake from incoming, production, supplier, audit, or complaint sources with Material Review Board (MRB) use-as-is, rework, scrap, or return dispositions.
  • CAPA workflows integrating Fishbone and 5-Whys root-cause tools, mandatory effectiveness checks prior to closure, and risk-file feedback links.
  • Complaint handling tied to lot eDHRs with guided vigilance decision trees, editable jurisdictional reporting clocks, Manufacturer Incident Report data sheets, and customer complaint portals.
  • Field Safety Corrective Actions (FSCA) and bidirectional recall trees tracing affected lots backward to raw materials and forward to every consignee.
  • Post-Market Surveillance plans, trend-alert thresholds, PSUR metric compilation, literature review logs, and installed-base firmware and service order tracking.
Internal Audits, Audit Trail, 64 Reports & Validation Pack

Connect internal audits and management reviews to Part 11 and Annex 11 aligned electronic signature logs, tamper-evident hash-chained audit trails, and a structured validation pack.

Commit-pinned on-premise or dedicated cloud deployments ensure controlled upgrade governance and strict role separation.

  • Internal audit programme mapped to ISO 13485 clauses and MDR articles generating NC/CAPA items, plus automated clause 5.6.2 management review inputs and quality objectives.
  • Tamper-evident hash-chained audit trail with verification checks and 21 CFR Part 11 / EU Annex 11 aligned re-authenticated e-signature logs.
  • Sixty-four print-ready documents spanning Device Master Summaries, Declarations of Conformity, D&D Files, Risk Files, FMEAs, eDHRs, Release Certificates, Labels, CAPAs, Field Safety Notices, and PSURs.
  • Thirteen role presets enforcing separation of duties—restricting QA Release and PRRC signing from system administrators.
  • Built-in Validation Pack combining editable intended-use statements, automated installation qualification (IQ) checks, requirements-to-test traceability matrices, and imported test evidence.
Stream — Digital Streams

Book a Live Demo & KSA ERP Readiness Review

Share your operational scope to receive a tailored walkthrough in Arabic or English, complete with a clear rollout roadmap and transparent estimate.

Protected under Saudi PDPL privacy standards · Response within 2 business hours